- Three Phase Induction Motor Definition: A three phase induction motor is defined as an electrical motor that is most widely used in industries due to its efficient power delivery and simple construction.
- Main Components: The motor is constructed from a stationary part called the stator and a rotating part called the rotor.
- Rotor Types: Rotor variations include the squirrel cage, which is maintenance-free and robust, and the slip ring or wound rotor, which allows for external resistance and better control at start-up.
- Applications: Three phase induction motors power various machinery in industries, including lathes, drilling machines, fans, and elevators.
- Operational Advantages: The squirrel cage motor is preferred for its simplicity and lower maintenance, while the slip ring motor is chosen for applications requiring high starting torque and adjustable speed.
The three phase induction motor is the most widely used electrical motor. Almost 80% of the mechanical power used by industries is provided by three phase induction motors because of its simple and rugged construction, low cost, good operating characteristics, the absence of commutator and good speed regulation. In three phase induction motor, the power is transferred from stator to rotor winding through induction. The induction motor is also called a synchronous motor as it runs at a speed other than the synchronous speed.
3 Phase Induction Motor Construction
Like any other type of electrical motor induction motor, a 3 phase induction motor is constructed from two main parts, namely the rotor and stator:
- Stator: The stator, a stationary part of the induction motor, contains the stator windings where the three phase supply is applied.
- Rotor: The rotor is a rotating part of induction motor. The rotor is connected to the mechanical load through the shaft.
The rotor of the three phase induction motor are further classified as
- Squirrel cage rotor
- Slip ring rotor or wound rotor or phase wound rotor.
Depending upon the type of rotor construction used the three phase induction motor are classified as:
- Squirrel cage induction motor
- Slip ring induction motor or wound induction motor or phase wound induction motor.
The construction of a stator for both of the kinds of three phase induction motors is identifcal, and is discussed briefly below. Please ensure you are using the appropriate electrical tools if you’re going to be deconstructing a motor yourself.
The other parts of a 3 phase induction motor are:
- Shaft for transmitting the torque to the load. This shaft is made up of steel.
- Bearings for supporting the rotating shaft.
- One challenge with electrical motors is heat production during operation. To mitigate this, a cooling fan is essential.
- For receiving external electrical connection Terminal box is needed.
- There is a small distance between rotor and stator which usually varies from 0.4 mm to 4 mm. Such a distance is called air gap.
You can learn more about induction motors by studying our electrical engineering MCQ.
Stator of Three Phase Induction Motor
The stator of the three-phase induction motor consists of three main parts :
- Stator frame,
- Stator core,
- Stator winding or field winding.
Stator Frame

It is the outer part of the three phase induction motor. Its main function is to support the stator core and the field winding. It acts as a covering, and it provides protection and mechanical strength to all the inner parts of the induction motor. The frame is either made up of die-cast or fabricated steel. The frame of three phase induction motor should be strong and rigid as the air gap length of three phase induction motor is very small. Otherwise, the rotor will not remain concentric with the stator, which will give rise to an unbalanced magnetic pull.
Stator Core
The main function of the stator core is to carry the alternating flux. In order to reduce the eddy current loss, the stator core is laminated. These laminated types of structure are made up of stamping which is about 0.4 to 0.5 mm thick. All the stamping are stamped together to form stator core, which is then housed in stator frame. The stamping is made up of silicon steel, which helps to reduce the hysteresis loss occurring in the motor.
Stator Winding or Field Winding
The slots on the periphery of the stator core of the three-phase induction motor carry three phase windings. We apply three phase ac supply to this three-phase winding. The three phases of the winding are connected either in star or delta depending upon which type of starting method we use. We start the squirrel cage motor mostly with star-delta stater and hence the stator of squirrel cage motor is delta connected. We start the slip ring three-phase induction motor by inserting resistances so, the stator winding of slip ring induction motor can be connected either in star or delta. The winding wound on the stator of three phase induction motor is also called field winding, and when this winding is excited by three phase ac supply, it produces a rotating magnetic field.
Types of Three Phase Induction Motor
Squirrel Cage Three Phase Induction Motor
The rotor of the squirrel cage three phase induction motor is cylindrical and have slots on its periphery. The slots are not made parallel to each other but are bit skewed (skewing is not shown in the figure of squirrel cage rotor besides) as the skewing prevents magnetic locking of stator and rotor teeth and makes the working of the motor more smooth and quieter. The squirrel cage rotor consists of aluminum, brass or copper bars (copper bras rotor is shown in the figure beside). These aluminum, brass or copper bars are called rotor conductors and are placed in the slots on the periphery of the rotor. The rotor conductors are permanently shorted by the copper, or aluminum rings called the end rings. To provide mechanical strength, these rotor conductors are braced to the end ring and hence form a complete closed circuit resembling like a cage and hence got its name as squirrel cage induction motor. The squirrel cage rotor winding is made symmetrical. As end rings permanently short the bars, the rotor resistance is quite small, and it is not possible to add external resistance as the bars get permanently shorted. The absence of slip ring and brushes make the construction of Squirrel cage three-phase induction motor very simple and robust and hence widely used three phase induction motor. These motors have the advantage of adopting any number of pole pairs. The below diagram shows a squirrel cage induction rotor having aluminum bars short circuit by aluminum end rings.
Advantages of Squirrel Cage Induction Rotor
- Its construction is very simple and rugged.
- As there are no brushes and slip ring, these motors requires less maintenance.
Applications of Squirrel Cage Induction Rotor
We use the squirrel cage induction motors in lathes, drilling machine, fan, blower printing machines, etc
Slip Ring or Wound Rotor Three Phase Induction Motor
In this type of three phase induction motor the rotor is wound for the same number of poles as that of the stator, but it has less number of slots and has fewer turns per phase of a heavier conductor. The rotor also carries star or delta winding similar to that of the stator winding.

The rotor consists of numbers of slots and rotor winding are placed inside these slots. The three end terminals are connected together to form a star connection. As its name indicates, three phase slip ring induction motor consists of slip rings connected on the same shaft as that of the rotor.
The three ends of three-phase windings are permanently connected to these slip rings. The external resistance can be easily connected through the brushes and slip rings and hence used for speed controlling and improving the starting torque of three phase induction motor. The brushes are used to carry current to and from the rotor winding. These brushes are further connected to three phase star connected resistances. An electrical diagram of a slip ring three phase induction motor is shown below:

At starting, the resistance is connected to the rotor circuit and is gradually cut out as the rotor pick up its speed. When the motor is running the slip ring are shorted by connecting a metal collar, which connects all slip ring together, and the brushes are also removed. This reduces the wear and tear of the brushes. Due to the presence of slip rings and brushes the rotor construction becomes somewhat complicated therefore it is less used as compare to squirrel cage induction motor.
Advantages of Slip Ring Induction Motor
- It has high starting torque and low starting current.
- Possibility of adding additional resistance to control speed.
Application of Slip Ring Induction Motor
Slip ring induction motor are used where high starting torque is required i.e in hoists, cranes, elevator etc.
Difference between Slip Ring and Squirrel Cage Induction Motor
| Slip ring or phase wound Induction motor | Squirrel cage induction motor |
| Construction is complicated due to presence of slip ring and brushes | Construction is very simple |
| The rotor winding is similar to the stator winding | The rotor consists of rotor bars which are permanently shorted with the help of end rings |
| We can easily add rotor resistance by using slip ring and brushes | Since the rotor bars are permanently shorted, its not possible to add external resistance |
| Due to presence of external resistance high starting torque can be obtained | Staring torque is low and cannot be improved |
| Slip ring and brushes are present | Slip ring and brushes are absent |
| Frequent maintenance is required due to presence of brushes | Less maintenance is required |
| The construction is complicated and the presence of brushes and slip ring makes the motor more costly | The construction is simple and robust and it is cheap as compared to slip ring induction motor |
| This motor is rarely used only 10% industry uses slip ring induction motor | Due to its simple construction and low cost. The squirrel cage induction motor is widely used |
| Rotor copper losses are high and hence less efficiency | Less rotor copper losses and hence high efficiency |
| Speed control by rotor resistance method is possible | Speed control by rotor resistance method is not possible |
| Slip ring induction motor are used where high starting torque is required i.e in hoists, cranes, elevator etc | Squirrel cage induction motor is used in lathes, drilling machine, fan, blower printing machines etc |