- DC Motor Definition: A DC motor is defined as a device that converts direct current electrical energy into mechanical energy.
- Stator and Rotor: The stator is the stationary part with field windings, and the rotor is the rotating part causing mechanical motion.
- Field Winding in DC Motor: Field winding, made of copper wire, generates a magnetic field for rotor operation by creating electromagnets with opposite polarities.
- Commutator Function: The commutator is a cylindrical structure that relays current from the power supply to the armature winding.
- Brushes and Their Role: Brushes made of carbon or graphite transfer current from the static circuit to the rotating commutator and armature.
A DC motor is a device that converts direct current electrical energy to mechanical energy (learn about a DC motor’s working principle).
A DC motor is constructed with:
- A Stator
- A Rotor
- A Yoke
- Poles
- Field windings
- Armature windings
- Commutator
- Brushes
A stator is the static part of the DC machine that houses the field windings and receives the supply. A rotor is the rotating part of the DC machine that brings about the mechanical rotations.
All these parts put together make up the total construction of a DC motor.

If you would prefer a video explanation, here is a video on the construction of DC machines:
Yoke of DC Motor
The magnetic frame or the yoke of DC motor made up of cast iron or steel and forms an integral part of the stator or the static part of the motor.

Its main function is to form a protective covering over the sophisticated inner parts of the motor and provide support to the armature. It also supports the field system by housing the magnetic poles and field winding of the DC motor.

Poles of DC Motor
The magnetic poles of a DC motor are fitted onto the yoke’s inner wall with screws. They consist of two parts: the pole core and the pole shoe. The pole core, with a small cross-sectional area, holds the pole shoe over the yoke. The pole shoe, with a larger cross-sectional area, spreads the magnetic flux over the air gap between the stator and rotor, reducing reluctance loss. It also has slots for the field windings that produce the field flux.
Field Winding of DC Motor

The field winding of a DC motor consists of copper wire coils wound over the pole shoe slots. When current flows through these coils, they create adjacent poles with opposite polarities. This forms an electromagnet that produces a magnetic field, causing the rotor armature to rotate within this field, effectively cutting the flux.
Armature Winding of DC Motor

The armature winding of a DC motor is attached to the rotor, which faces changing magnetic fields during rotation, causing magnetic losses. To reduce these losses, the rotor is made of an armature core composed of laminated silicon steel sheets. These laminations minimize hysteresis and eddy current losses and form the cylindrical structure of the armature core.
The armature core are provided with slots made of the same material as the core to which the armature winding made with several turns of copper wire distributed uniformly over the entire periphery of the core. The slot openings a shut with fibrous wedges to prevent the conductor from plying out due to the high centrifugal force produced during the rotation of the armature, in presence of supply current and field.

The construction of armature winding of DC motor can be of two types:-
Lap Winding
In this case the number of parallel paths between conductors A is equal to the number of poles P.
i.e A = P
***An easy way of remembering it is by remembering the word LAP—–→ L A = P
Wave Winding
Here in this case, the number of parallel paths between conductors A is always equal to 2 irrespective of the number of poles. Hence the machine designs are made accordingly.
Commutator of DC Motor

The commutator of a DC motor is a cylindrical structure made of copper segments, insulated by mica. Its main function is to relay the supply current from the mains to the armature winding on the rotating structure, through the brushes.
Brushes of DC Motor
The brushes of DC motor are made with carbon or graphite structures, making sliding contact over the rotating commutator. The brushes are used to relay the current from external circuit to the rotating commutator form where it flows into the armature winding. So, the commutator and brush unit of the DC motor is concerned with transmitting the power from the static electrical circuit to the mechanically rotating region or the rotor.