- Wiedemann Franz Law Definition: The Wiedemann-Franz law is defined as the relationship between thermal conductivity and electrical conductivity in materials with free electrons, typically metals.
- Thermal and Electrical Conductivity: Both properties measure how well a material conducts heat and electricity, respectively, and are influenced by temperature.
- Temperature Impact: Higher temperatures increase electron velocity, improving heat transfer but reducing electrical conductivity due to more collisions.
- Historical Context: The law is named after Gustav Wiedemann and Rudolph Franz, who discovered the ratio of these conductivities in 1853.
- Law’s Limitations: The Wiedemann-Franz law isn’t valid at intermediate temperatures and varies for different materials.
The Wiedemann-Franz law relates the thermal conductivity (κ) and electrical conductivity (σ) of materials with freely moving electrons, typically found in metals.
- Thermal Conductivity (κ): It is the degree (measure) of capacity of a material to conduct heat.
- Electrical Conductivity (σ): It is the degree (measure) of capacity of a material to conduct electricity.
In metals; when temperature increases, the velocity of free electrons increases and that leads to an increase in heat transfer and it also increases the collisions between the lattice ions and free electrons. This results in the drop in electrical conductivity.
The law states that the ratio of thermal conductivity to electrical conductivity in a material is directly proportional to its temperature.
This law is named after Gustav Wiedemann and Rudolph Franz in 1853 reported that the ratio has more or less the similar value for dissimilar metal at the same temperature.
Derivation of the Law
For that, we have to assume a homogeneous isotropic material. This material is then subjected to a temperature gradient . The direction of the heat flow will be opposite to that of the temperature gradient all the way through the conducting medium.
The heat flowing through the material per unit time per unit area is the heat flux. It will be proportional to the temperature gradient.
K → Coefficient of thermal conductivity (W/mK)
K = Kphonon + Kelectron; since the transfer of heat in solids owing to phonon and electron.
Now, we can derive the expression for coefficient of thermal conductivity.
For that, we have to assume the flow of heat is from higher temperature to lower temperature in a metal slab which has a temperature gradient of .
cv → Specific heat
n → Number of particles per unit volume
λ → mean free path of collisions
v → velocity of electrons
Comparing the equations (1) and (2), we get
We know that the energy of free electrons is
We put the equation (4) in (3)
Now, the specific heat for an ideal gas at constant volume,
When we put equation (8) in (6), we get
Next, we can consider the electrical current density of a metal with the application of electric field, E (figure 1)
J = σ E ; Ohms law
So, the correct form of Ohms law is given by
There is a mean free path and mean time between the collisions.
e → Charge of the electron = 1.602 × 10-9 C
τ → Collision time or mean time: It is the average time for the electron to move or travel prior to scattering.
vd → Drift Velocity: It is the standard velocity of the electron during the collision time.
When we put equation (11) in (10), we get electrical conductivity (Drude Conductivity) as
Consider the electrons which move in a metal without any application of electrical field. Then the equipartition theorem is given by
From equation (13) we get m as
Now, we put equation (14) in (12)
Thus, we obtain the values of K and σ from equations (6) and (15).
Now, we can take the ratio
We assume v = vd, then equation (16) becomes
From this, we can say that the ratio is similar for all the metals. It is also a function of temperature. This law is known as Wiedemann-Franz Lorenz Law. We can conclude that the most excellent electrical conductor will be a best thermal conductor.
Limitations of Wiedemann Franz Law
- The value of L is not the same for all the materials.
- This law is not valid for intermediate temperature.
- In the pure metals, both σ and κ increases as temperature decreases.

