- Describing Function Definition: The describing function is an approximate method for analyzing nonlinear control systems by relating the amplitudes and phase angles of fundamental harmonic components.
- Nonlinear Systems Analysis: Nonlinear systems cannot use traditional linear analysis methods, requiring specialized techniques like the describing function.
- Common Nonlinearities: Common types of nonlinearities include saturation, friction, dead zone, relay, and backlash, each affecting system behavior differently.
- Saturation Nonlinearity: Saturation occurs when an output is proportional to an input only within a specific range, leading to nonlinear behavior beyond this range.
- Relay Nonlinearity: Relay nonlinearity involves control signals with distinct states, such as ON/OFF, often introducing characteristics like hysteresis and dead zones.
The describing function is an approximate procedure for analyzing certain nonlinear control problems in control engineering. To start, let us first recall the basic definition of a linear control system. Linear control systems are those where the principle of superposition (if the two inputs are applied simultaneously, then the output will be the sum of two outputs) is applicable. In the case of highly nonlinear control systems, we are unable to apply the principle of superposition.
Analyzing nonlinear control systems is challenging due to their complex behavior. Conventional methods like the Nyquist stability criterion or pole-zero method cannot be used, as they are only for linear systems. However, nonlinear systems do offer some advantages:
- Nonlinear systems can perform better than linear systems.
- Nonlinear systems are less costly than linear systems.
- They are usually small and compact in size as compared to linear systems.
In practice, all physical systems have some form of nonlinearity. Sometimes, adding a nonlinearity intentionally can improve a system’s performance or make it safer, ultimately making it more economical than a linear system.
An example of an intentionally introduced nonlinearity is a relay-controlled or ON/OFF system. For instance, in a home heating system, the furnace turns ON when the temperature drops below a set value and OFF when it exceeds another value. We will discuss two methods for analyzing nonlinear systems with examples.
- Describing function method in control system
- Phase plane method in control system
Common Non Linearities
In most types of control systems, certain nonlinearities are unavoidable. These can be classified as static or dynamic. Static nonlinearity exists when there’s a nonlinear relationship between input and output without involving a differential equation. Dynamic nonlinearity involves input and output related through a nonlinear differential equation.
Now we are going to discuss various types of non-linearities in a control system:
- Saturation nonlinearity
- Friction nonlinearity
- Dead zone nonlinearity
- Relay nonlinearity (ON OFF controller)
- Backlash nonlinearity
Saturation Nonlinearity
Saturation nonlinearity is a common type of nonlinearity. For example see this nonlinearity in the saturation in the magnetizing curve of DC motor. In order to understand this type of nonlinearity let us discuss saturation curve or magnetizing curve which is given below:
From the above curve we can see that the output showing linear behavior in the beginning but after that there is a saturation in the curve which one kind of non linearity in the system. We have also shown approximated curve.
Same type of saturation non linearity also we can see in an amplifier for which the output is proportional to the input only for a limited range of values of input. When the input exceeds this range, the output tends to become non linearity.
Friction Nonlinearity
Anything which opposes the relative motion of the body is called friction. It is a kind of non linearity present in the system. The common example in an electric motor in which we find coulomb friction drag due to the rubbing contact between the brushes and the commutator.
Friction may be of three types and they are written below:
- Static Friction : In simple words, the static friction acts on the body when the body is at rest.
- Dynamic Friction : Dynamic friction acts on the body when there is a relative motion between the surface and the body.
- Limiting Friction : It is defined as the maximum value of limiting friction that acts on the body when it is at rest.
Dynamic friction can also be classified as (a) Sliding friction (b) Rolling friction. Sliding friction acts when two bodies slides over each other while rolling acts when the bodies rolls over another body.
In mechanical system we have two types of friction namely (a) Viscous friction (b) Static friction.
Dead Zone Nonlinearity
Dead zone nonlinearity is shown in various electrical devices like motors, DC servo motors, actuators etc. Dead zone non linearities refer to a condition in which output becomes zero when the input crosses certain limiting value.
Relays Nonlinearity (ON/OFF Controller)
Electromechanical relays are frequently used in control systems where the control strategy requires a control signal with only two or three states. This is also called as ON/OFF controller or two state controller.
Relay Non-Linearity (a) ON/OFF (b) ON/OFF with Hysteresis (c) ON/OFF with Dead Zone. Fig (a) shows the ideal characteristics of a bidirectional relay. In practice, relay will not respond instantaneously. For input currents between the two switching instants, the relay may be in one position or other depending upon the previous history of the input. This characteristic is called ON/OFF with hysteresis that shows in Fig (b). A relay also has a definite amount of dead zone in practice that show in Fig (c). The dead zone is caused by the fact that the relay field winding requires a finite amount of current to move the armature.
Backlash Nonlinearity
Another important nonlinearity commonly occurring in the physical system is hysteresis in mechanical transmissions such as gear trains and linkages. This nonlinearity is somewhat different from magnetic hysteresis and is commonly referred to as backlash nonlinearities. Backlash in fact is the play between the teeth of the drive gear and those of the driven gear. Consider a gearbox as shown in below figure (a) having backlash as illustrated in fig (b).
Fig (b) shows the teeth A of the driven gear located midway between the teeth B1, B2 of the driven gear. Fig (c) gives the relationship between input and output motions. As the teeth A is driven clockwise from this position, no output motion takes place until the tooth A makes contact with the tooth B1 of the driven gear after traveling a distance x/2. This output motion corresponds to the segment mn of fig (c). After the contact is made the driven gear rotates counterclockwise through the same angle as the drive gear if the gear ratio is assumed to be unity. This is illustrated by the line segment no. As the input motion is reversed, the contact between the teeth A and B1 is lost and the driven gear immediately becomes stationary based on the assumption that the load is friction controlled with negligible inertia.
The output motion, therefore, causes till tooth A has traveled a distance x in the reverse direction as shown in fig (c) by the segment op. After the tooth A establishes contact with the tooth B2, the driven gear now mores in a clockwise direction as shown by segment pq. As the input motion is reversed the direction gear is again at standstill for the segment qr and then follows the drive gear along rn.
Describing Function Analysis of Nonlinear Systems
The describing function method in control system was invented by Nikolay Mitrofanovich Kryloy and Nikolay Bogoliubov in year of 1930 and later it developed by Ralph Kochenburger.
The describing function method is used for finding out the stability of a non linear system of all the analytical methods developed over the years for non linear control systems, this method is generally agreed upon as being the most practically useful. This method is basically an approximate extension of frequency response methods including Nyquist stability criterion to non linear system.
The describing function method of a non linear system is defined to be the complex ratio of amplitudes and phase angle between fundamental harmonic components of output to input sinusoid. We can also called sinusoidal describing function. Mathematically,
Where,
N = describing function,
X = amplitude of input sinusoid,
Y = amplitude of the fundamental harmonic component of output,
φ1 = phase shift of the fundamental harmonic component of output.
Let us discuss the basic concept of describing the function of non linear control system.
Let us consider the below block diagram of a non linear system, where G1(s) and G2(s) represent the linear element and N represent the non linear element.
Let us assume that input x to the non linear element is sinusoidal, i.e,
For this input, the output y of the non linear element will be a non sinusoidal periodic function that may be expressed in terms of Fourier series as
Most of nonlinearities are odd symmetrical or odd half wave symmetrical; the mean value Y0 for all such case is zero and therefore output will be,
As G1(s) G2(s) has low pass characteristics, it can be assumed to a good degree of approximation that all higher harmonics of y are filtered out in the process, and the input x to the nonlinear element N is mainly contributed by fundamental component of y i.e. first harmonics. So in the describing function analysis, we assume that only the fundamental harmonic component of the output. Since the higher harmonics in the output of a non linear system are often of smaller amplitude than the amplitude of fundamental harmonic component. Most control systems are low pass filters, with the result that the higher harmonics are very much attenuated compared with the fundamental harmonic component.
Hence, y1 need only be considered.
We can write y1(t) in the form,
Where by using phasor,
The coefficient A1 and B1 of the Fourier series are given by-
From definition of describing function we have,
Let us find out describing function for these non linearities.
Describing Function for Saturation Non Linearity
We have the characteristic curve for saturation as shown in the given figure.
Let us take input function as
Now from the curve we can define the output as:
Let us first calculate Fourier series constant A1.
On substituting the value of the output in the above equation and integrating the function from 0 to 2π we have the value of the constant A1 as zero.
Similarly we can calculate the value of Fourier constant B1 for the given output and the value of B1 can be calculated as,

The phase angle for the describing function can be calculated as
Thus the describing function for saturation is
Describing Function for Ideal Relay
We have the characteristic curve for ideal relay as shown in the given figure.
Let us take input function as
Now from the curve we can define the output as
The output periodic function has odd symmetry :
Let us first calculate Fourier series constant A1.
On substituting the value of the output in the above equation and integrating the function from 0 to 2π we have the value of the constant A1 as zero.
Similarly we can calculate the value of Fourier constant B1 for the given output and the value of B1 can be calculated as
On substituting the value of the output in the above equation y(t) = Y we have the value of the constant B1
And the phase angle for the describing function can be calculated as
Thus the describing function for an ideal relay is
Describing Function for Real Relay (Relay with Dead Zone)
We have the characteristic curve for real realy as shown in the given figure. If X is less than dead zone Δ, then the relay produces no output; the first harmonic component of Fourier series is of course zero and describing function is also zero. If X > Δ the relay produces the output.
Let us take input function as
Now from the curve we can define the output as

The output periodic function has odd symmetry :
Let us first calculate Fourier series constant A1.
On substituting the value of the output in the above equation and integrating the function from 0 to 2π we have the value of the constant A1 as zero.
Similarly we can calculate the value of Fourier constant B for the given output and the value of B can be calculated as
Due to the symmetry of y, the coefficient B1 can be calculated as follows,
Therefore, the describing function is
Describing Function for Backlash Non Linearity
We have the characteristic curve for backlash as shown in the given figure. Let us take input function as

Now from the curve we can define the output as
Let us first calculate Fourier series constant A1.
On substituting the value of the output in the above equation and integrating the function from zero to 2π we have the value of the constant A1 as
Similarly we can calculate the value of Fourier constant B for the given output and the value of B1 can be calculated as
On substituting the value of the output in the above equation and integrating the function from zero to pi we have the value of the constant B1 as
We can easily calculate the describing function of backlash from below equation