- Tree Definition: A tree in network analysis is defined as a set of branches that include all nodes of the network without forming any closed paths.
- Twigs: The branches of a tree are known as twigs, and they connect all nodes without loops.
- Cotree Definition: A cotree is formed from the branches not included in the tree and is called links or chords.
- Tree and Cotree Relationship: The sum of the branches in a tree and its cotree equals the total number of branches in the network.
- Kirchhoff’s Laws: The number of independent Kirchhoff Voltage Law equations equals the number of links in the cotree, and the number of Kirchhoff Current Law equations equals the number of twigs in the tree.
Let us explain the tree of electric network as defined above.
The above figure-1, shows an electric network with five nodes 1,2,3,4 and 5.
Now, if we remove the branches 1-2, 2-3, 3-4 and 4-1 from the circuit, we will get, the graph as shown below in figure-2.
The graph in figure-2 contains all five nodes of the network without forming any closed paths. This is an example of a tree in an electric network.
Multiple trees can be formed in a single electric circuit, each containing the same five nodes without any closed loops.


The branches of a tree are also known as twigs.
In figure-2, figure-3 and figure-4 we can see that, there are four twigs or branches of tree in each tree of that electric network. The number of nodes in the network is 5.
So, in this case,
This is a general equation for all trees of any electric network. The general equation is normally written as,
Where, l is the number of branches in a tree and n is the number of nodes in the network from which the trees are formed.
Cotrees of Electric Network
When forming a graph from an electric network, certain branches are chosen. The branches not included in the tree are called links or chords. The graph made from these links is called a cotree. A cotree can be open or closed depending on the links.


The cotrees are shown in the above figures by red colour. It is found from figure-5, figure-6 and figure-7 that, the sum of number of branches of tree and its cotree is the total number branches of electric network.
So, if number of links of a cotree is l’, then
Where, l is the number of twigs in the tree and b is the number of branches in a network. So,
Where, n is the number of nodes in the electric network.
Properties of Tree of Electric Netwrok
- A tree consists of all the nodes of the electric network.
- A tree has the number of branches which is less than 1 of number of nodes of the electric network.
- A tree must not have any closed path in any part of it.
- There may be many different possible trees in same electric network.
- The sum of the number of branches in a tree and number of branches of its cotree is equal to the total number of branches of their electric network.
- The number of independent Kirchhoff Voltage Law equations can be formed for an electric network is equal to its number of links or chords of cotree.
- The number of independent Kirchhoff Current Law equations can be formed for an electric network is equal to the its number of twigs

