- Nickel Iron Battery Definition: A Nickel Iron Battery, also known as an Edison Battery, is defined as a robust and long-lasting battery with high tolerance for overcharging and discharging.
- Efficiency: Nickel Iron Batteries have a charging efficiency of 65% and a discharging efficiency of 85%, which means they store and deliver energy effectively.
- Lifespan: These batteries can last between 30 to 100 years, much longer than traditional lead-acid batteries.
- Components: The battery uses nickel(III) hydroxide for the cathode, iron for the anode, and potassium hydroxide as the electrolyte, with additional materials to enhance conductivity.
- Advantages and Disadvantages: They are durable and lightweight but have high initial costs and lower efficiency compared to other batteries.
Which battery is becoming more popular day by day as there is a huge scope of development to turn the battery into high energy density battery for an electric vehicle? The answer would be Nickel Iron Battery or Edison Battery. In a single word, a Ni-Fe battery is a very robust battery. This battery has a very high tolerance for overcharging, over discharging, short-circuiting, etc. This battery can perform equally well even we do not charge the battery for a long period. Due to its heavy weight, this battery is used in those applications where the weight of the battery does not matter, for example, in the solar energy system, in wind energy system, etc. as a backup. Durability and lifespan of a nickel-iron cell are much higher than that of a lead acid battery, but still, the nickel-iron battery has lost its popularity because of its high manufacturing cost.
Let’s have a look at some specific features of nickel-iron (Ni-Fe) or Edison battery.
The Nickel Iron Battery can deliver 30 to 50 kW of energy per kilogram. Its charging efficiency is about 65%, meaning 65% of the input energy is stored as chemical energy. Its discharging efficiency is about 85%, so it can deliver 85% of the stored energy to the load. If unused for 30 days, it loses only 10-15% of its energy due to self-discharging. These batteries have a lifespan of 30 to 100 years, much longer than the 10-year lifespan of lead acid battery. The nominal voltage per nickel iron cell is 1.4 V.
Nickel Iron Battery
The basic components used in Nickel iron battery are nickel(III) hydroxide as the cathode, iron as anode and potassium hydroxide as the electrolyte. We add Nickel sulfate and Ferrous sulfide to the active material.
Construction of Edison Batteries
The capacity of a Ni-Fe cell depends on the size and number of positive and negative plates. Both plates look the same and consist of a rectangular grid made of nickel-plated iron. Each grid hole is filled with a shallow, finely perforated nickel-plated steel box.
Although both of the plates are appeared to be same, they contain different active materials. Perforated nickel-plated steel boxes of positive plates contain a mixture of an oxide of nickel and pulverized carbon, and some of the negative plates contain fine grains of the oxide of iron with the fine dust of carbon. In both the plates, the fine dust of carbon, mixed with active materials, helps to increase electrical conductivity. We use 20% diluted caustic potash as an electrolyte.
Nickel plated iron gets used to make the vessel containing electrolyte and electrodes. Ebonite sticks are placed between the plates of different polarities to prevent them from coming into direct contact and causing a short circuit. There is another specialty in the construction of Edison battery or nickel iron battery, which the number of negative plates is one more than that of the number of positive plates, and we electrically connect the last negative plate to the container. Plates of same polarities are welded to a common strap, and they make a cell, and combining several cells, the battery gets constructed.
Operation of Nickel Iron Batteries
The main operation of the nickel-iron battery involves a chemical reaction called electrolysis. Electrolysis occurs when current flows, causing or resulting from a chemical reaction. The chemistry of the nickel-iron cell is complex, with the exact formula for the positive active material not fully established. Assuming the material is Ni(OH)3, during charging, the nickel compound on the positive plates oxidizes to nickel peroxide, while the charging process changes the iron compound on the negative plates to spongy iron.
In the fully charged condition, the active material of the positive plates is nickel hydroxide [Ni(OH)3], while that in pockets of the negative plate is iron, Fe. When the cell delivers current to load, the active material of the positive plate changes from Ni(OH)3 to Ni(OH)2 and that of the negative plate changes from iron to Ferrous hydroxide (Fe(OH)2). The electrochemical process in the Edison battery can be expressed by the equation
The equation expresses both the phenomenon of charging and discharging. The right side flow of the equation is the reaction of the discharging phenomenon, and the left side flow of the equation expresses the charging phenomenon. The reaction occurs by transfer of electrons through the external circuit to the positive plate during discharge. There is a provision for giving off the corrosive fume which is generated during the electrolysis inside the battery so that no special care is needed in mounting the cell.
Characteristics of Nickel Iron Batteries
The emf of a fully charged Edison battery is 1.4 V. The average discharge voltage is about 1.2 V and the average charging voltage is about 1.7 V per cell. The characteristics of this type of battery are shown below in the figure.
The voltage characteristics of the Nickel Iron battery are similar to the lead-acid cell. A fully charged battery starts with an emf of 1.4 V, which slowly decreases to 1.3 V and then very slowly to 1.1 or 1.0 V during discharge. There is no lower limit for discharging emf, meaning the battery will eventually stop providing output. The emf of a battery increases with temperature.
The average time of charging of a battery is 7 hours and discharging time is 5 hours. Another characteristic of Edison battery is that continuous operation at higher temperature decreases the life of the battery, the same thing happens if the battery is charged for more than the average time of charging.
The ampere-hour and watt-hour efficiency of this nickel-iron battery is 85 % and 60 % respectively. At 4oC temperature, the capacity of Edison battery falls to zero, that’s why the battery should be heated up before operation though during operation the I2R loss keeps the battery hot and running.
Advantages of Nickel Iron Batteries
There are various Advantages of Edison battery , these are listed below.
- The weight of this battery is lower than other types of battery because they need less amount of electrolytes and plates are also lighter.
- The service life of the battery is much higher because of various provisions made.
- These types of battery are stronger, have rugged construction because of the steel body. For this reason, they are not affected by vibrations, jolts or shocks, heavy currents and do not suffer during short circuits.
Disadvantages of Nickel Iron Batteries
There are certain disadvantages of Edison battery, like the initial cost needed for making these batteries are pretty high as the materials used are highly priced. Another drawback of these type of battery is the low efficiency. For this few reasons the use of these batteries is restricted, they are mainly used in the areas where high mechanical strength, lightness, freedom from acid fumes are needed.
Application of Nickel Iron Batteries
From the above discussions, we already know that the said battery is mainly used in extreme conditions or it can be said that where there is no other way than using Edison battery. These batteries are mainly used in industrial trucks for propulsion purpose. They are also used in mine locomotives and for railways, car lighting, and air conditioning because they have pretty high mechanical strength.
Maintenance and Care of Nickel Iron Batteries
We already know that these batteries need lower maintenance than other types of battery. The main precaution taken for these types of battery is to maintain the level of electrolyte present inside the battery. Because, if the level of the electrolyte becomes lower than the plates inside, the battery get damaged very quickly, and the battery suffers irreversible damage. To prevent this, the battery should get filled with distilled water at least once in a week. Another maintenance which is needed for this battery is to change the electrolyte solution time to time, whenever the specific gravity of the solution falls below 1.16 the electrolyte gets changed. Lastly, it is important to consider that the battery should be discharged to zero volts before taking it out for servicing for a long period.