Tellegen Theorem

💡
Key learnings:
  • Tellegen’s Theorem Definition: Tellegen’s theorem is defined as the principle that the sum of instantaneous powers in all branches of an electrical network is zero.
  • Importance in Network Analysis: Tellegen’s theorem is crucial for analyzing electrical networks by ensuring power balance.
  • Conditions for Application: The theorem applies to networks satisfying Kirchhoff’s Current Law and Kirchhoff’s Voltage Law.
  • Example Demonstration: An example network with specific voltages and currents shows how Tellegen’s theorem works in practice.
  • Applicability: It applies to various types of network elements, including linear, non-linear, active, and passive components.
bernard d.h. tellegen


This theorem has been introduced in the year of 1952 by Dutch Electrical Engineer Bernard D.H. Tellegen. This is a very useful theorem in network analysis. According to Tellegen theorem, the summation of instantaneous powers for the n number of branches in an electrical network is zero. Are you confused? Let’s explain. Suppose n number of branches in an electrical network have i1, i2, i3, …………. in respective instantaneous currents through them. These currents satisfy Kirchhoff’s Current Law.

Again, suppose these branches have instantaneous voltages across them are v1, v2, v3, ……….. vn respectively. If these voltages across these elements satisfy Kirchhoff Voltage Law then,

vk is the instantaneous voltage across the kth branch and ik is the instantaneous current flowing through this branch. Tellegen theorem is applicable to lumped networks that consist of linear, non-linear, time variant, time-invariant, and active and passive elements.

tellegen theorem

This theorem can easily be explained by the following example.
In the given network, arbitrary directions are chosen for branch currents, and corresponding branch voltages are indicated with the positive direction at the tail of the current arrow.
In this network, we assume that the branch voltages satisfy Kirchhoff’s Voltage Law and the branch currents satisfy Kirchhoff’s Current Law at each node.

We will then show that these arbitrary assumed voltages and currents satisfy the equation.

And it is the condition of Tellegen theorem.
In the network shown in the figure, let v1, v2 and v3 be 7, 2 and 3 volts respectively. Applying Kirchhoff Voltage Law around loop ABCDEA. We see that v4 = 2 volt is required. Around loop CDFC, v5 is required to be 3 volt and around loop DFED, v6 is required to be 2. We next apply Kirchhoff’s Current Law successively to nodes B, C and D.

At node B let ii = 5 A, then it is required that i2 = – 5 A. At node C let i3 = 3 A and then i5 is required to be – 8. At node D ssume i4 to be 4 then i6 is required to be – 9. Carrying out the operation of equation,

We get,
Hence Tellegen theorem is verified.