- Strain Gauge Definition: A strain gauge is a device that measures the deformation (strain) of an object when force is applied, through changes in electrical resistance.
- Working Principle: The strain gauge detects minute geometrical changes as resistance changes, which indicate the level of stress on the material.
- Bridge Circuit: The strain gauge is part of a bridge circuit, where it helps detect imbalances in resistance that correspond to stress, measured by a central voltmeter.
- Temperature Compensation: To address temperature-induced resistance changes, strain gauges often include compensation techniques using materials like constantan alloy or dummy gauges.
- Common Uses: Employed extensively in mechanical engineering, strain gauges analyze stress on machinery and structural components, crucial for safety and functionality.
What is a Strain Gauge
A strain gauge is a resistor used to measure strain on an object. When an external force is applied on an object, due to which there is a deformation occurs in the shape of the object. This deformation in the shape is both compressive or tensile is called strain, and it is measured by the strain gauge. When an object deforms within the limit of elasticity, either it becomes narrower and longer or it become shorter and broadens. As a result of it, there is a change in resistance end-to-end.
The strain gauge is sensitive to small changes in an object’s geometry, allowing it to calculate the amount of induced stress by measuring resistance changes.
The strain gauge, which features a thin metallic strip in a zigzag pattern on a non-conductive carrier, detects minute resistance changes. This design amplifies the slight stresses for accurate measurement. The gauge is adhered to the device with a strong adhesive.
Physical deformations in an object lead to changes in electrical resistance, which the strain gauge measures accurately.
Strain Gauge Bridge Circuit
Strain gauge bridge circuit shows the measured stress by the degree of discrepancy, and uses a voltmeter in the center of the bridge to provide an accurate measurement of that imbalance:

In this circuit, R1 and R3are the ratio arms equal to each other, and R2 is the rheostat arm has a value equal to the strain gage resistance. When the gauge is unstrained, the bridge is balanced, and voltmeter shows zero value. As there is a change in resistance of strain gauge, the bridge gets unbalanced and producing an indication at the voltmeter. The output voltage from the bridge can be amplified further by a differential amplifier.
Variation of Temperature of Strain Gauge
One more factor that affects the resistance of the gauge is temperature. If the temperature is more resistance will be more and if the temperature is less the resistance will be less. This is a common property of all the conductors. We can overcome this problem by using strain gauges that are self- temperature-compensated or by a dummy strain gauge technique.
Most of the strain gauges are made of constantan alloy which cancel out the effect of temperature on the resistance. But some strain gauges are not of an isoelastic alloy. In such cases, dummy gauge is used in the place of R2 in the quarter bridge strain gauge circuit which acts as a temperature compensation device.
Whenever temperature changes, the resistance will change in the same proportion in the both arms of the rheostat, and the bridge remains in the state of balance. Effect of temperature get nullifies. It is good to keep voltage low so that the self-heating of strain gauge could be evaded. Self-heating of gauge depends upon its mechanical behavior.
This arrangement is considered as quarter-bridge. There are two more arrangements half-bridge and full-bridge configurations which give greater sensitivity over the quarter-bridge circuit. Still the quarter-bridge circuit is widely used in strain measurement systems.
Use of Strain Gauge
- In the field of mechanical engineering development.
- To measure the stress generated by machinery.
- In the field of component testing of aircraft like; linkages, structural damage etc.