- Servo Motor Controller Definition: A servo motor controller (or servo motor driver) is defined as a circuit used to control the position of a servo motor.
- Servo Motor Driver Circuit: The servo motor driver circuit includes a micro-controller, power supply, potentiometer, and connectors, ensuring precise motor control.
- Micro-controller Role: The micro-controller generates PWM pulses at specific intervals to control the servo motor’s position accurately.
- Power Supply: Servo motors need a stable power supply between 4.8V to 6V, with higher current ratings for multiple motors.
- Program Algorithm: The program algorithm involves initializing ports, reading ADC for position, programming PWM registers, and managing pulse width with a timer.
A servo motor driver can control a single servo or a group of servo motors. In many projects, where controlling multiple servos is essential, the controller must manage several motors. For example, an RC airplane uses many servos.
Essential Components
- A micro-controller
- A power supply unit
Miscellaneous Components
- A potentiometer
- Connectors, wires etc.
Micro-controller
A servo motor is driven by applying the voltage signal to it regular intervals. The servo is sensitive to timing variations. A pulse of specific width has to be applied at specific intervals of time. Typically, the duration of pulse varies from 0ms to 2.2ms and the repetition rate is 50Hz to 60Hz. For precise position control, the controller that is chosen must have timers that have the required resolution. Also, if more than one motor has to be controlled simultaneously, the processor clock must be fast enough. For a single motor control, an 8051 can be used like a AT89s51 or a P89v51RD2. But for more than one motor, we must use a PIC, like a PIC18F or a ATMEGA, so that it’s internal PWM can be utilized. However, the selection of micro-controller depends totally on the designer and the project requirements.
Power Supply
The power supply design for a servo motor controller depends on the number of connected motors. Servo motors typically use a 4.8V to 6V supply, with 5V being standard. Exceeding the supply voltage can damage the motor. The current draw varies with the torque and is lower in idle mode and higher when running. The maximum current draw, known as stall current, can reach up to 1A for some motors.
For single motor control, use a voltage regulator like LM317 with a heat sink. For multiple motors, a high-quality power supply with a higher current rating is necessary. An SMPS (Switched Mode Power Supply) is a good choice.
Block Diagram below-showing interconnections in a Servo Motor Driver
Controlling Servo Motor
The servo motor has three terminals.
- Position signal(PWM Pulses)
- Vcc (From Power Supply)
- Ground

The servo motor’s angular position is controlled by applying PWM pulses of specific widths. The pulse duration ranges from about 0.5ms for 0-degree rotation to 2.2ms for 180-degree rotation. The pulses should be given at frequencies around 50Hz to 60Hz.
In order to generate the PWM (Pulse Width Modulation) waveform, as shown in the figure below, one can use either the internal PWM module of the micro-controller or the timers can be used. Using the PWM block is more flexible as most micro-controller families design, and this PWM block better suits the needs of applications such as a servo motor. For different widths of PWM pulses, we need to program the internal registers accordingly.
Now, we also need to tell the microcontroller how much it has to rotate. For this purpose, we can use a simple potentiometer and use an ADC to get the rotation angle or for more complex applications an accelerometer can be used.
Program Algorithm
Let us design the Program to control a single servo and the position input is given via the potentiometer connected to a pin of controller.
- nitialize the port pins for input/output.
- Read the ADC for desired servo position.
- Program the PWM registers for the desired value.
As soon as you trigger the PWM module, the selected PWM channel pin goes high (logic 1) and after the required width is reached, it will again go low (logic 0). So after triggering the PWM, you must start a timer with a delay of about 19 ms and wait until the timer overflows - Go to step 2
There are various modes of PWM available which you can use depending on the microcontroller you choose. Some degree of optimization should be done in the code to control the servo.
If you plan to use more than one servo than you will require as many PWM channels. Each servo can be given the PWM signal sequentially. But you must take care that the pulse repetition rate for each servo is maintained. Otherwise the servo will run out of synchronization.
Note :
If you plan on making your own board for the servo motor controller, give proper thickness for tracks carrying the current to the servo. Proper ERC and DRC rule check must be followed. The PWM signals for a continuous rotation servo are not same as that of a 180 degree servo. The servo datasheet should be consulted for such motors.
A servo motor is critical to voltage fluctuations and too high voltage may damage the internal feedback control circuit. So the power supply must be thoroughly designed to the servo specifications and checked before deployment. Heat sink must be used if necessary.