- Initial Value Theorem Definition: The Initial Value Theorem is defined as a method to find the initial value of a function using its Laplace transform.
- Conditions for Initial Value Theorem: For IVT to work, the function and its derivative must be Laplace transformable and must exist as t approaches 0+.
- Proof of Initial Value Theorem: IVT is proved by manipulating the Laplace transform of a function and its derivative.
- Applications of Initial Value Theorem: IVT simplifies finding the initial value of functions in practical applications without solving the function itself.
- Limitations: IVT cannot be applied if the function contains impulses or if the numerator polynomial is of higher order than the denominator.
Initial Value Theorem is one of the basic properties of Laplace transform. It was given by prominent French Mathematical Physicist Pierre Simon Marquis De Laplace. He made crucial contributions in the area of planetary motion by applying Newton’s theory of Gravitation. His work regarding the theory of probability and statistics is considered pioneering and this influenced a whole new generation of Mathematician. Laplace is one among the 72 people to have their name engraved on the Eiffel Tower.
The Initial Value Theorem (IVT) and the Final Value Theorem are known as Limiting Theorems. IVT helps us find the initial value at time t = (0+) for a given Laplace transformed function. This saves us the effort of finding f(t) directly, which can be very tedious.
Conditions for the existence of Initial value theorem
- The function f(t) and its derivative f(t) should be Laplace transformable.
- If time t approaches to (0+) then the function f(t) should exists.

- The function f(t) = 0 for t > 0 and contains no impulses or higher order singularities at origin.
Statement of Laplace Initial Value Theorem
If f(t) and F(s) is Laplace transform pairs. i.e
then Initial value theorem is given by
Proof of Laplace Initial Value Theorem
Laplace transform of a function f(t) is
then Laplace transform of its derivative f ‘ (t) is
Consider the integral part first

Substituting (2) in (1) we get
Upon cancelling f (0–) on both sides we get
We can straightaway write the above equation but my intension on taking the limits of integration from (0– to ∞) is that however we consider the negative values of limits it pertains to the results having positive values.
Note:
We also knew that Laplace transform is applicable only for causal functions.
On considering (s) tends to infinity on both sides in (3)
Hence, Initial value theorem is proved.
Applications of Initial Value Theorem
The purpose of the Initial Value Theorem is to determine the initial value of the function f(t) given its Laplace transform.
Example 1 :
Find the initial value for the function f (t) = 2 u (t) + 3 cost u (t)
Sol:
By initial value theorem
The initial value is given by 5.
Example 2:
Find initial value of the transformed function
Sol:
By initial value theorem
[as s → ∞ the values of s become more and more insignificant hence the result is obtained by simply taking the ratio of leading co-efficient]
Example 3:
Find the initial value of
Solution:
Initial value theorem is not applicable in this case. We can prove it in two ways.
Let’s see how it goes
Method 1:
Note:
This theorem is applicable strictly if F (s) is proper fraction i.e the numerator polynomial is of lower order than the denominator polynomial.
In case if IVT is applied we get ∞ as the initial value.
[this is not possible in practical circuits ]
Aliter:
Applying Inverse Laplace transform
It is obvious that Initial value theorem is not applicable since there is impulse function, which is constant over time t.
By this discussion, it is easy for one to manipulate the initial conditions of the circuit with the Laplace transformed function.