Brushless DC Motors (BLDC): What Are They & How Do They Work?

💡
Key learnings:
  • BLDC Motor Definition: A brushless DC motor is defined as an electronically commutated motor that lacks brushes, enhancing operational efficiency and torque.
  • Core Components: The two primary components of a BLDC motor are the rotor, which rotates, and the stator, which remains stationary.
  • Operational Efficiency: BLDC motors excel in efficiency due to their brushless design, which eliminates friction losses and allows precise speed control.
  • Design Types: There are two main types of BLDC motor designs—inner rotor and outer rotor, each influencing the motor’s performance and heat management.
  • Advantages and Disadvantages: BLDC motors offer greater efficiency and longevity but tend to cost more and require careful handling to prevent heat damage.

What is a Brushless Motor?

A brushless DC motor (also known as a BLDC motor or BL motor) is an electronically commuted DC motor which does not have brushes. The controller provides pulses of current to the motor windings which control the speed and torque of the synchronous motor.

BLDC motors produce significant torque across a broad speed range, thanks to permanent magnets rotating around a stationary armature. Their electronic commutation offers flexible capabilities, ensuring smooth operation and steady torque even when stationary.

What is a Brushless Motor

How Does a Brushless Motor Work

Before explaining the working of a brushless DC motor, it is better to understand the function of a brushed motor. In brushes motors, there are permanent magnets on the outside and a spinning armature which contains electromagnet is inside. These electromagnets create a magnetic field in the armature when the power is switched on and help to rotate the armature.

The brushes change the polarity of the pole to keep the rotation on of the armature. The basic working principle for the brushed DC motor and for brushless DC motor are same i.e. internal shaft position feedback.

A BLDC motor consists of two primary parts: the rotor (rotating) with magnets, and the stator (stationary) with windings. Permanent magnets on the rotor interact with the stator’s electromagnets, controlled by high-power transistors and a solid-state circuit for power distribution.

Types of Brushless DC Motors

There are two types of BLDC motors: outer rotor and inner rotor designs. While their working principles are identical, the designs differ mainly in the placement of components.

Inner Rotor Design

In an inner rotor design, the rotor is located in the centre of the motor and the stator winding surround the rotor. As the rotor is located in the core, rotor magnets do not insulate heat inside and heat get dissipated easily. Due to this reason, inner rotor designed motor produces a large amount of torque and validly used.

Brushless Motor

Outer Rotor Design

In outer rotor design, the rotor surrounds the winding which is located in the core of the motor. The magnets in the rotor trap the heat of the motor inside and do not allow to dissipate from the motor. Such type of designed motor operates at lower rated current and has low cogging torque.

BLDC Motor

Advantages of Brushless DC Motor

The advantages of a BLDC motor are:

  1. Brushless motors are more efficient as its velocity is determined by the frequency at which current is supplied, not the voltage.
  2. As brushes are absent, the mechanical energy loss due to friction is less which enhanced efficiency.
  3. BLDC motor can operate at high-speed under any condition.
  4. There is no sparking and much less noise during operation.
  5. More electromagnets could be used on the stator for more precise control.
  6. BLDC motors accelerate and decelerate easily as they are having low rotor inertia.
  7. It is high performance motor that provides large torque per cubic inch over a vast sped rang.
  8. BLDC motors do not have brushes which make it more reliable, high life expectancies, and maintenance free operation.
  9. There is no ionizing sparks from the commutator, and electromagnetic interference is also get reduced.
  10. Such motors cooled by conduction and no air flow are required for inside cooling.

Disadvantages of Brushless DC Motors

The disadvantages of a BLDC motor are:

  1. BLDC motor cost more than a brushed DC motor.
  2. Only limited high power should be supplied to a BLDC motor; excessive heat can weaken the magnets and damage the winding’s insulation.