Video thumbnail for Full Pitch and Short Pitch Winding (Worked Example)

Full Pitch and Short Pitch Winding (Worked Example)

Jun 6, 2024
A SIMPLE explanation of Full Pitch and Short Pitch Winding. Understand what Full Pitch and Short Pitch Windings are, and what Coil Span is. You can read more about Full Pitch and Short Pitch Winding at: https://www.electrical4u.com/armature-winding-pole-pitch-coil-span-commutator-pitch/ Comment below with any additional questions you have. If you enjoyed this video and want to see more like it, please LIKE and SUBSCRIBE to our Youtube channel. The pole pitch is defined as the peripheral distance between the center of two adjacent poles in DC machine. This distance is measured in term of armature slots or armature conductor come between two adjacent pole centers. Pole Pitch is naturally equal to the total number of armature slots divided by the number of poles in the machine. If there are 96 slots on the armature periphery and 4 numbers of poles in the machine, the numbers of armature slots come between two adjacent poles centers would be 96/4 = 24. Hence, the pole pitch of that DC machine would be 24. As we have seen that, pole pitch is equal to total numbers of armature slots divided by total numbers of poles, we alternatively refer it as armature slots per pole. Coil of dc machine is made up of one turn or multi turns of the conductor. If the coil is made up of single turn or a single loop of conductor, it is called single turn coil. If the coil is made up of more than one turn of a conductor, we refer it as a multi-turn coil. A single turn coil will have one conductor per side of the coil whereas, in multi turns coil, there will be multiple conductors per side of the coil. Whatever may be the number of conductors per side of the coil, each coil side is placed inside one armature slot only. That means all conductors of one side of a particular coil must be placed in one single slot only. Similarly, we place all conductors of the opposite side of the coil in another single armature slot. Coil span is defined as the peripheral distance between two sides of a coil, measured in term of the number of armature slots between them. That means, after placing one side of the coil in a particular slot, after how many conjugative slots, the other side of the same coil is placed on the armature. This number is known as coil span.
#Electricity