- Motor Duty Class Definition: Motor duty class is defined as the categorization of motors based on their operating times and cooling periods.
- Continuous Duty: These motors run long enough to reach steady state temperature, used in paper mills, compressors, and conveyors.
- Short Time Duty: These motors have short operating times with longer cooling periods, ideal for cranes, household appliances, and valves.
- Intermittent Periodic Duty: These motors operate with alternating periods of running and rest, seen in presses and drilling machines.
- Classes of Motor Duty: Different classes include continuous duty, short time duty, and intermittent periodic duty, each suited for specific applications.
Nowadays, electric motors are used in almost every application, controlled by electrical drives. However, not all motors operate for the same amount of time. Some run continuously, while others have shorter run times with longer rest periods. This difference introduces the concept of motor duty class, which divides motor duty cycles into eight categories:
- Continuous duty
- Short time duty
- Intermittent periodic duty
- Intermittent periodic duty with starting
- Intermittent periodic duty with starting and braking
- Continuous duty with intermittent periodic loading
- Continuous duty with starting and braking
- Continuous duty with periodic speed changes

Continuous Duty
This duty denotes that, the motor is running long enough AND the electric motor temperature reaches the steady state value. These motors are used in paper mill drives, compressors, conveyors etc.

Short Time Duty
These motors operate for short periods, and their heating time is much less than their cooling time. Thus, the motor cools down to ambient temperature before operating again. These motors are used in crane drives, household appliances, and valve drives.



Intermittent Periodic Duty
In this duty, the motor runs for a while and then rests. Neither period is long enough to reach steady state temperature or cool down completely. This type is used in press and drilling machine drives.
Intermittent Period Duty with Starting
In this type of drives, heat loss during starting and braking cannot be ignored. So, the corresponding periods are starting period, operating period, braking period and resting period, but all the periods are too short to attain the respective steady state temperatures, these techniques are used in billet mill drive, manipulator drive, mine hoist etc.
Continuous Duty with Intermittent Periodic Loading
This motor duty is similar to periodic duty, but it includes a no-load running period instead of a rest period. Examples include pressing and cutting machines.
Continuous Duty with Starting and Braking
It is also a period of starting, running and braking and there is no resting period. The main drive of a blooming mill is an example.
Continuous Duty with Periodic Speed Changes
In this type of motor duty, there are different running periods at different loads and speeds. But there is no rest period and all the periods are too short to attain the steady state temperatures.