- Electrical Polarity Definition: Electrical polarity is defined as the state of a body or system relative to another, indicating whether it has positive or negative polarity.
- Importance of Polarity: Polarity is crucial for connecting devices like meters, machines, and batteries correctly.
- Current Flow Direction: In a DC circuit, current flows in one direction—from negative to positive polarity—while in an AC circuit, current changes direction every half cycle.
- Polarity in Voltage Sources: In circuits with multiple voltage sources, the total voltage depends on the polarity of the sources—same polarity adds up, opposite polarity subtracts.
- Conventional vs Actual Current Direction: Conventionally, current is assumed to flow from positive to negative, but in reality, it flows from negative to positive due to electron movement.
What is Electrical Polarity?
Electrical polarity is used to define the state of a body or system with respect to other bodies or systems. It is a relative quantity.
Electrical polarity is classified into two types—
- Positive polarity
- Negative polarity
The polarity of a body or system that has a greater number of electrons is considered the negative polarity. And the polarity of the remaining body or system is considered the positive polarity.
Polarity plays an important role in connecting devices like measuring meters, electrical machines, and batteries correctly.
The electrical polarity is also used to determine the flow of current. Polarity is also referred to in terms of “terminals”, i.e. as the positive and negative terminals.
In power sources, current flows from the positive to the negative terminal. In circuit elements like resistors, it flows from the negative to the positive terminal.
In a DC circuit, the current flows in one direction. Let’s consider a simple DC circuit shown in the figure below.

Here, the current flow in a clockwise direction because the current leaves from the negative polarity of the battery or source.
In a DC circuit, the polarity of voltage sources and voltage drops are denoted by ‘+’ (positive polarity) and ‘-‘ (negative polarity).
AC Polarity
The direct current flows in one direction only. It is a constant current. But an alternating current (AC) changes its polarity from every half cycle.
For 50Hz current, the waveform changes its polarity at each 10ms. And the polarity changes 100 times in one second.

In a DC system, magnitude and polarity are enough to describe it. In an AC system, you must also consider an angle (time-shift between two signals) along with magnitude and polarity.
The voltage is never signed negative (-) in the AC system. The polarity of the source will decide to either add or subtract.
How Does Electrical Polarity Work?
The electrical polarity gives information about the direction of current through the circuit. The polarity depends on the number of electrons.
If there are more electrons, it is called negative polarity. The other side is positive polarity.
The electrical polarity decides the direction of the flow of current. Also, it is very important if more than one voltage source is connected to the circuit.
Consider a DC circuit with two sources. If both sources have the same polarity, the total available voltage is added. And if both sources have opposite polarity, the total available voltage is subtracted.

In the first figure, both sources have the same polarity. Hence, the total voltage available to the circuit is 10V.
In the second figure, the polarity of both sources is opposite. Hence, the total voltage available is 2V.
Now consider an AC circuit with two voltage sources. Here, magnitude, polarity, and phase angle are used to find the equivalent voltage.

In the first figure, both sources have the same polarity. Hence, the equivalent voltage is the addition of both. But these are the polar form—
![]()
![]()
First, we need to convert this polar form into a rectangular form. And it will be—
![]()
![]()
Now, the equivalent voltage is the addition of each of the X-components and Y-components (i.e.
)—
![]()
Again, convert the rectangular form into polar form and we will get—
![]()
In the second figure, both sources have opposite polarities. In this case, the equivalent voltage is a subtraction of both voltages—
![]()
Now, we can add both
and
to find an equivalent voltage—
![]()
![]()
![]()
![]()
Now, convert this rectangular form into polar form—
![]()
As above, we can see that the electrical polarity is a key factor of consideration when calculating the equivalent voltage of multiple voltage sources.
Conventions for Identification
According to the polarity, we can find the direction of the current flowing through the active and passive components.
In the passive element, ohm’s law gives a relation between voltage and current. But the voltage polarity and current direction are necessary to assign.
Voltage polarity and current direction are interconnected. The conventional identification of voltage polarity and current direction in passive elements is illustrated in the figure below.

So, according to convention law, the current flows from positive polarity to negative polarity. But in actuality, the current flows from negative polarity to positive polarity.
In conventional identification, we assumed the current flows due to proton (positive charge). But according to the actual definition of current, it is the flow of electrons (negative charge).
And there is no difference if we consider the conventional or actual direction.