× Home MCQ Videos Basic Electrical Circuit Theories Electrical Laws Materials Batteries Illumination Generation Transmission Distribution Switchgear Protection Measurement Control System Utilities Safety Transformer Motor Generator Electrical Drives Electronics Devices Power Electronics Digital Electronics Biomedical Instrumentation

Generation

Generation of Electric Power

1. Primary Sources of Electrical Energy
2. Power Plants and Types of Power Plant
3. Electric Power Generation
4. Cogeneration | Combined Heat and Power
5. MHD Generation or Magneto Hydro Dynamic Power Generation
6. Thermoelectric Power Generators or Seebeck Power Generation

Steam Power Station

1. Thermal Power Generation Plant or Thermal Power Station
2. Flow Diagram of a Steam Thermal Power Plant
3. Economiser in Thermal Power Plant | Economiser
4. Duplex Feed Water Pump
5. Deaerating Heater | Deaerator
6. What is Water Hammer?
7. Steam Turbine


Hydro Power Station

1. Hydro Power Plant | Construction Working and History of Hydro power plant

Nuclear Power Station

1. Nuclear Power Station or Nuclear Power Plant
2. Nuclear Reactor

Diesel Power Station

1. Diesel Power Station

Gas Turbine Power Station

1. Gas Turbine Power Plant
2. Schematic Diagram of Gas Turbine Power Plant

Tariff and Economics

1. Economics of Power Generation
2. Cost of Electrical Energy
3. Calorific Values of Fuel
4. Unit of Electrical Energy

Solar Power Generation

1. Solar Electricity
2. Solar Energy System | History of Solar Energy
3. Types of Solar Power Station
4. Components of a Solar Electric Generating System
5. What is Photovoltaic Effect?
6. Solar Cell
7. Working Principle of Solar Cell or Photovoltaic Cell
8. Characteristics of a Solar Cell and Parameters of a Solar Cell
9. Solar Cell Manufacturing Technology
10. What is a Solar PV Module?
11. What is Standalone Solar Electric System?
12. Solar Lantern
13. Staebler Wronski Effect

Wind power Generation

1. Wind Energy Electricity Generation
2. Theory of Wind Turbine
3. Wind Turbine | Working and Types of Wind Turbine
4. Basic Construction of Wind Turbine
5. Wind Turbine Introduction

Fire Protection of Power Plant

1. Power Plant Fire Protection System
2. Hydrant System for Power Plant Fire Protection
3. Medium Velocity Water Spray or MVWS System for Fire Protection
4. Foam Fire Protection System
5. Fire Detection and Alarm System
6. Gas Extinguishing System

Boiler

1. Steam Boiler | Working principle and Types of Boiler
2. Water Tube Boiler | Operation and Types of Water Tube Boiler
3. Fire Tube Boiler | Operation and Types of Fire Tube Boiler
4. Stirling Boiler
5. Cyclone Fired Boiler
6. Feed Water and Steam Circuit of Boiler
7. Boiler Feed Water Treatment Demineralization Reverse Osmosis Plant Deaerator
8. Boiler Economiser

Steam System

1. What is Steam?
2. Superheated Steam and Steam Phase Diagram
3. Steam Dryness Fraction
4. Effective Steam Distribution System
5. What is Steam Flashing?
6. Vapour Properties Mollier Chart Heat Capacities
7. How to Calculate Steam Consumption During Plant Start Up

Combustion

1. Methods of Firing Steam Boiler
2. Coal Combustion Theory
3. Principle of Solid Fuel Firing
4. Pulverized Fuel Firing of Boiler
5. Fluidized Bed Combustion | Types and Advantages
6. Steam Boiler Furnace Grate Firebox Combustion Chamber of Furnace
7. Electric Arc Furnace

Electrostatic Precipitator

1. Working Principle of Electrostatic Precipitator
2. Types of Electrostatic Precipitator
3. Components of Electrostatic Precipitator
4. Advantages and Disadvantages of Electrostatic Precipitator
5. Electrostatic Precipitator Efficiency

Steam Condenser

1. Steam Condenser of Turbine
2. Surface Steam Condenser
3. Jet Condenser | Low Level High Level Ejector Jet Condenser

Draught and Chimney

1. Natural Draught and Chimney
2. Artificial Draught
3. Steam Jet Draught
4. Types and Working of Cooling Tower
5. Cooling Tower Useful Terms and Cooling Tower Performance
6. Cooling Tower Material and Main Components
7. Natural Draft Cooling Towers

Thermodynamics

1. Engineering Thermodynamics Part 1
2. Science of Engineering Thermodynamics Part 2
3. Basic Law of Conservation and First Law of Thermodynamics
4. Carnot Cycle and Reversed Carnot Cycle
5. Enthalpy Entropy and Second Law of Thermodynamics
6. Rankine Cycle
7. Rankine Cycle and Regenerative Feed Heating
8. Rankine Cycle for Closed Feed Water Heaters and Rankine Cycle Cogeneration
9. Ideal Verses Actual Rankine Cycle
10. Rankine Cycle Efficiency Improvement Techniques


New Articles
Indoor SwitchgearEEG MeasurementElectroencephalography | EEGECG Recording SetupElectrocardiography
Articles Categories
MCQ Videos Basic Electrical Circuit Theories Electrical Laws Materials Batteries Illumination Generation Transmission Distribution Switchgear Protection Measurement Biomedical Instrumentation Control System Utilities Safety Transformer Motor Generator Electrical Drives Electronics Devices Power Electronics Digital Electronics Guest Post