Cyclone Fired Boiler

Cyclone fired boiler uses cyclone furnace. Cyclone furnace is one of the most modern forms of the furnace. Cyclone furnace is a variety of wet bottom furnace where ash gets removed from the furnace in molten form. The furnace in the cyclone-fired boiler is in the form of a horizontal cylinder. The furnace requires the … Read more

Stirling Boiler

Stirling Boiler is one of the most basic variety of bent tube boiler. In most of the modern thermal power generating plants we use bent tube boiler. Stirling Boiler is one of the largest capacity boiler. A Stirling Boiler can generate as high as 50,000 kg steam per hour and can produce pressure as high … Read more

Boiler Economiser

After producing steam, the flue gas comes out from the system. Some heat energy remains in the flue gas when it goes out. If we cannot utilise this heat energy, it gets lost. Boiler economiser is a device which uses a portion this remained energy of the flue gas to heat up inlet water (feed … Read more

Steam Boiler | Working principle and Types of Boiler

Boiler or more specifically steam boiler is an essential part of thermal power plant. Definition of Boiler Steam boiler or simply a boiler is basically a closed vessel into which water is heated until the water is converted into steam at required pressure. This is most basic definition of boiler. Working Principle of Boiler The … Read more

Fire Tube Boiler | Operation and Types of Fire Tube Boiler

Fire tube boiler is one of the most basic types of boiler and the design is also very old. It was popular in 18th century. It was mainly used for steam locomotive engines. Operation of Fire Tube Boiler Operation of fire tube boiler is as simple as its construction. In fire tube boiler, the fuel … Read more

Water Tube Boiler | Operation and Types of Water Tube Boiler

A water tube boiler is such kind of boiler where the water is heated inside tubes and the hot gasses surround them. This is the basic definition of water tube boiler. Actually this boiler is just opposite of fire tube boiler where hot gasses are passed through tubes which are surrounded by water. Advantages of … Read more

Boiler Feed Water Treatment Demineralization Reverse Osmosis Plant Deaerator

All natural sources of water contain impurities as well as dissolved gasses. The amount of these impurities depends on type of water source and location. Why it is necessary to treat the raw water? Raw water coming from different sources contains dissolved salts and un-dissolved or suspended impurities. It is necessary to remove harmful salts … Read more

Feed Water and Steam Circuit of Boiler

There are different components present in feed water and steam circuit of boiler and we should know some essential components of these circuit and these are Economizer, boiler drums, water tubes, and super heater. Economizer Economizer is a heat exchanger which takes heat from the flue gas, and increases the temperature of feed water coming … Read more