Introduction to Power Electronic Converters

The field of Power Electronics mainly deals with the conversion of power from one form to another and the change from one voltage level to another by using different power electronic converters. There are many control strategies used in the converters to aid this conversion. Another important aspect of using power converters is conditioning. Conditioning … Read more

Buck Converter | Step Down Chopper

DC-DC converters are also known as Choppers. Here we will have a look at the Step Down Chopper or Buck converter which reduces the input DC voltage to a specified DC output voltage. A typical Buck converter is shown below. The input voltage source is connected to a controllable solid state device which operates as … Read more

Boost Converter | Step Up Chopper

DC-DC converters are also known as Choppers. Here we will have a look at the Step Up Chopper or Boost converter which increases the input DC voltage to a specified DC output voltage. A typical Boost converter is shown below. The input voltage source is connected to an inductor. The solid-state device which operates as … Read more

Buck Boost Converter

DC-DC converters are also known as Choppers. Here we will have a look at Buck Boost converter which can operate as a DC-DC Step-Down converter or a DC-DC Step-Up converter depending upon the duty cycle, D. A typical Buck-Boost converter is shown below. The input voltage source is connected to a solid state device. The … Read more

Chopper | DC to DC Converter

DC to DC converter is very much needed nowadays as many industrial applications are dependent upon DC voltage source. The performance of these applications will be improved if we use a variable DC supply. It will help to improve controllability of the equipments also. Examples of such applications are subway cars, trolley buses, battery operated … Read more

Cycloconverter

The main electrical energy forms commonly available are in constant DC (direct current) and constant AC (alternating current). Yet for various applications, the several forms of these two energies are used. For this conversion purpose, several converters like inverters, rectifiers, choppers and cycloconverters are employed. The cycloconverters can in fact transfer AC power of a … Read more

Dual Converter

Dual converter, the name itself says two converters. It is really an electronic converter or circuit which comprises of two converters. One will perform as rectifier and the other will perform as inverter. Therefore, we can say that double processes will occur at a moment. Here, two full converters are arranged in anti-parallel pattern and … Read more

Advantages and Disadvantages of Power Electronic Converters

Power Electronics has seen a tremendous growth in recent times and almost all the applications today use power electronic devices in some or the other form. Hence it becomes essential to study the advantages of these devices, which made it so popular. Listed below are some of the advantages and disadvantages of power electronic converters: … Read more

Three Phase Full Wave Diode Rectifier

A three phase full wave diode rectifier with purely resistive load is shown below. The AC voltage supply is 110 V line to line and 50 Hz frequency. The waveform of the voltage across the load is shown in black in the figure below. Vm-phase is the maximum of phase voltage. The minimum of the … Read more